15 research outputs found

    Clinical evaluation of a novel adaptive bolus calculator and safety system in Type 1 diabetes

    Get PDF
    Bolus calculators are considered state-of-the-art for insulin dosing decision support for people with Type 1 diabetes (T1D). However, they all lack the ability to automatically adapt in real-time to respond to an individual’s needs or changes in insulin sensitivity. A novel insulin recommender system based on artificial intelligence has been developed to provide personalised bolus advice, namely the Patient Empowerment through Predictive Personalised Decision Support (PEPPER) system. Besides adaptive bolus advice, the decision support system is coupled with a safety system which includes alarms, predictive glucose alerts, predictive low glucose suspend for insulin pump users, personalised carbohydrate recommendations and dynamic bolus insulin constraint. This thesis outlines the clinical evaluation of the PEPPER system in adults with T1D on multiple daily injections (MDI) and insulin pump therapy. The hypothesis was that the PEPPER system is safe, feasible and effective for use in people with TID using MDI or pump therapy. Safety and feasibility of the safety system was initially evaluated in the first phase, with the second phase evaluating feasibility of the complete system (safety system and adaptive bolus advisor). Finally, the whole system was clinically evaluated in a randomised crossover trial with 58 participants. No significant differences were observed for percentage times in range between the PEPPER and Control groups. For quality of life, participants reported higher perceived hypoglycaemia with the PEPPER system despite no objective difference in time spent in hypoglycaemia. Overall, the studies demonstrated that the PEPPER system is safe and feasible for use when compared to conventional therapy (continuous glucose monitoring and standard bolus calculator). Further studies are required to confirm overall effectiveness.Open Acces

    Accuracy and impact on quality of life of real-time continuous glucose monitoring in children with hyperinsulinaemic hypoglycaemia

    Get PDF
    Objective: Continuous glucose monitoring (CGM) is the standard of care for glucose monitoring in children with diabetes, however there are limited data reporting their use in hyperinsulinaemic hypoglycaemia (HH). Here, we evaluate CGM accuracy and its impact on quality of life in children with HH. Methods: Real-time CGM (Dexcom G5 and G6) was used in children with HH aged 0-16years. Data from self-monitoring capillary blood glucose (CBG) and CGM were collected over a period of up to 28days and analysed. Quality of life was assessed by the PedsQL4.0 general module and PedsQL2.0 family impact module, completed by children and their parents/carers before and after CGM insertion. Analysis of accuracy metrics included mean absolute relative difference (MARD) and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of reference glucose values >100 mg/dL or ≤100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses. Results: Prospective longitudinal study with data analysed from 40 children. The overall MARD between reference glucose and paired CGM values (n=4,928) was 13.0% (Dexcom G5 12.8%, Dexcom G6 13.1%). The proportion of readings meeting %15/15 and %20/20 were 77.3% and 86.4%, respectively, with CEG analysis demonstrating 97.4% of all values in zones A and B. Within the hypoglycaemia range (<70 mg/dL), the median ARD was 11.4% with a sensitivity and specificity of 64.2% and 91.3%, respectively. Overall PedsQL child report at baseline and endpoint were 57.6 (50.5 – 75.8) and 87.0 (82.9 – 91.2), and for parents were 60.3 (44.8 – 66.0) and 85.3 (83.7 – 91.3), respectively (both p<0.001). Conclusion: Use of CGM for children with HH is feasible, with clinically acceptable accuracy, particularly in the hypoglycaemic range. Quality of life measures demonstrate significant improvement after CGM use. These data are important to explore use of CGM in disease indications, including neonatal and paediatric diabetes, cystic fibrosis and glycogen storage disorders. Highlight

    A modular safety system for an insulin dose recommender: A feasibility study

    Get PDF
    Background: Delivering insulin in type 1 diabetes is a challenging, and potentially risky, activity; hence the importance of including safety measures as part of any insulin dosing or recommender system. This work presents and clinically evaluates a modular safety system that is part of an intelligent insulin dose recommender platform developed within the EU-funded PEPPER project. Methods: The proposed safety system is composed of four modules which use a novel glucose forecasting algorithm. These modules are: predictive glucose alerts and alarms; a predictive low-glucose basal insulin suspension module; an advanced rescue carbohydrate recommender for resolving hypoglycaemia; and a personalised safety constraint applied to insulin recommendations. The technical feasibility of the proposed safety system was evaluated in a pilot study including eight adult subjects with type 1 diabetes on multiple daily injections over a duration of six weeks. Glycaemic control and safety system functioning were compared between the two-weeks run-in period and the end-point at eight weeks. A standard insulin bolus calculator was employed to recommend insulin doses. Results: Overall, glycaemic control improved over the evaluated period. In particular, percentage time in the hypoglycaemia range (<3.0mmol/l) significantly decreased from 0.82 (0.05-4.79) % at run-in to 0.33 (0.00-0.93) % at endpoint (p=0.02). This was associated with a significant increase in percentage time in target range (3.9-10.0mmol/l) from 52.8 (38.3-61.5) % to 61.3 (47.5-71.7) % (p=0.03). There was also a reduction in number of carbohydrate recommendations. Conclusion: A safety system for an insulin dose recommender has been proven to be a viable solution to reduce the number of adverse events associated to glucose control in type 1 diabetes

    Accuracy and impact on quality of life of real-time continuous glucose monitoring in children with hyperinsulinaemic hypoglycaemia

    Get PDF
    ObjectiveContinuous glucose monitoring (CGM) is the standard of care for glucose monitoring in children with diabetes, however there are limited data reporting their use in hyperinsulinaemic hypoglycaemia (HH). Here, we evaluate CGM accuracy and its impact on quality of life in children with HH.MethodsReal-time CGM (Dexcom G5 and G6) was used in children with HH aged 0-16years. Data from self-monitoring capillary blood glucose (CBG) and CGM were collected over a period of up to 28days and analysed. Quality of life was assessed by the PedsQL4.0 general module and PedsQL2.0 family impact module, completed by children and their parents/carers before and after CGM insertion. Analysis of accuracy metrics included mean absolute relative difference (MARD) and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of reference glucose values &gt;100 mg/dL or ≤100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses.ResultsProspective longitudinal study with data analysed from 40 children. The overall MARD between reference glucose and paired CGM values (n=4,928) was 13.0% (Dexcom G5 12.8%, Dexcom G6 13.1%). The proportion of readings meeting %15/15 and %20/20 were 77.3% and 86.4%, respectively, with CEG analysis demonstrating 97.4% of all values in zones A and B. Within the hypoglycaemia range (&lt;70 mg/dL), the median ARD was 11.4% with a sensitivity and specificity of 64.2% and 91.3%, respectively. Overall PedsQL child report at baseline and endpoint were 57.6 (50.5 – 75.8) and 87.0 (82.9 – 91.2), and for parents were 60.3 (44.8 – 66.0) and 85.3 (83.7 – 91.3), respectively (both p&lt;0.001).ConclusionUse of CGM for children with HH is feasible, with clinically acceptable accuracy, particularly in the hypoglycaemic range. Quality of life measures demonstrate significant improvement after CGM use. These data are important to explore use of CGM in disease indications, including neonatal and paediatric diabetes, cystic fibrosis and glycogen storage disorders

    A survey of current practices by the British Oculoplastic Surgery Society (BOPSS) and recommendations for delivering a sustainable multidisciplinary approach to thyroid eye disease in the United Kingdom

    Get PDF
    The Royal College of Physicians (RCP) and Thyroid Eye Disease Amsterdam Declaration Implementation Group (TEAMeD-5) have the common goal of improving access to high quality care for thyroid eye disease (TED). The TEAMeD-5 programme recommends all patients with moderate-to-severe TED should have access to multidisciplinary clinics (MDT) with combined Ophthalmology and Endocrinology expertise

    Rationale and protocol for the Assessment of Impact of Real-time Continuous Glucose Monitoring on people presenting with severe Hypoglycaemia (AIR-CGM) study

    No full text
    Background: Severe hypoglycaemia carries a significant risk of morbidity and mortality for people with type 1 diabetes. Economic costs are also high, estimated at approximately £13 million annually in England, UK. Continuous glucose monitoring (CGM) has been shown to reduce hypoglycaemia and associated fear, improve overall glycaemia and quality of life, and is cost-effective. Despite effective pathways in place with high levels of resource utilization, it has been reported there are low levels of follow-up, therapy change and specialist intervention after severe hypoglycaemia. This study is designed to assess the impact of providing real-time CGM to people with type 1 diabetes, who have had a recent episode of severe hypoglycaemia (within 72hours), compared to standard care. Methods/Design: Fifty-five participants with type 1 diabetes and a recent episode of severe hypoglycaemia, who are CGM naïve, will be recruited to the study. Participants will be randomised to CGM or standard care. The primary outcome is percentage time spent in hypoglycaemia (<3.0mmol/L, 55mg/dL). Secondary outcomes include other measures of hypoglycaemia, time in euglycaemia, overall glucose status and patient reported qualitative measures. Discussion: This study assesses the impact of providing continuous glucose monitoring at the outset in individuals at highest risk of hypoglycaemia. Changing demand means that novel approaches need to be taken to healthcare provision. This study has the potential to shape future national standards

    How Can Point-of-Care Technologies Support In-Hospital Diabetes Care?

    Full text link
    People with diabetes admitted to hospital are at risk of diabetes related complications including hypoglycaemia and diabetic ketoacidosis. Point-of-care (POC) tests undertaken at the patient bedside, for glucose, ketones, and other analytes, are a key component of monitoring people with diabetes, to ensure safety. POC tests implemented with a quality framework are critical to ensuring accuracy and veracity of results and preventing erroneous clinical decision making. POC results can be used for self-management of glucose levels in those well-enough and/or by healthcare professionals to identify unsafe levels. Connectivity of POC results to electronic health records further offers the possibility of utilising these results proactively to identify patients ‘at risk’ in real-time and for audit purposes. In this article, the key considerations when implementing POC tests for diabetes in-patient management are reviewed and potential to drive improvements using networked glucose and ketone measurements are discussed. In summary, new advances in POC technology should allow people with diabetes and the teams looking after them whilst in hospital to integrate to provide safe and effective care

    variation in the current use of technology to support diabetes management in UK hospitals: Results of a survey of healthcare professionals

    No full text
    Background: There has been a significant increase in the use of wearable diabetes technologies in the outpatient setting over recent years, but this has not consistently translated into inpatient use. Methods: An online survey was undertaken to understand the current use of technology to support inpatient diabetes care in the United Kingdom. Results: Responses were received from 42 different organizations representing 104 hospitals across the United Kingdom. Significant variation was found between organizations in the use of technology to support safe, effective inpatient diabetes care. Benefits of the use of technology were reported, and areas of good practice identified. Conclusion: Technology supports good inpatient diabetes care, but there is currently variation in its use. Guidance has been developed which should drive improvements in the use of technology and hence improvements in the safety and effectiveness of inpatient diabetes care. Key recommendations include implementation of this guidance (especially for continuous glucose monitoring), ensuring specialist support is available for the use of wearable diabetes technology in hospital, optimizing information sharing across the health care system, and making full use of data from networked glucose and ketone meters.</p

    DataSheet_1_Accuracy and impact on quality of life of real-time continuous glucose monitoring in children with hyperinsulinaemic hypoglycaemia.docx

    No full text
    ObjectiveContinuous glucose monitoring (CGM) is the standard of care for glucose monitoring in children with diabetes, however there are limited data reporting their use in hyperinsulinaemic hypoglycaemia (HH). Here, we evaluate CGM accuracy and its impact on quality of life in children with HH.MethodsReal-time CGM (Dexcom G5 and G6) was used in children with HH aged 0-16years. Data from self-monitoring capillary blood glucose (CBG) and CGM were collected over a period of up to 28days and analysed. Quality of life was assessed by the PedsQL4.0 general module and PedsQL2.0 family impact module, completed by children and their parents/carers before and after CGM insertion. Analysis of accuracy metrics included mean absolute relative difference (MARD) and proportion of CGM values within 15, 20, and 30% or 15, 20, and 30 mg/dL of reference glucose values >100 mg/dL or ≤100 mg/dL, respectively (% 15/15, % 20/20, % 30/30). Clinical reliability was assessed with Clarke error grid (CEG) analyses.ResultsProspective longitudinal study with data analysed from 40 children. The overall MARD between reference glucose and paired CGM values (n=4,928) was 13.0% (Dexcom G5 12.8%, Dexcom G6 13.1%). The proportion of readings meeting ?/15 and /20 were 77.3% and 86.4%, respectively, with CEG analysis demonstrating 97.4% of all values in zones A and B. Within the hypoglycaemia range (ConclusionUse of CGM for children with HH is feasible, with clinically acceptable accuracy, particularly in the hypoglycaemic range. Quality of life measures demonstrate significant improvement after CGM use. These data are important to explore use of CGM in disease indications, including neonatal and paediatric diabetes, cystic fibrosis and glycogen storage disorders.</p